■KEY FEATURES
••Universal input :100-240Vac(90-264Vac)
• Complete protection function: OCP. OVP.
OLP.OTP.SCP,ULVO
• ESD: Air ±15kV Contact ±8kV
• Power Factor correction design,PF>0.95
• Turn on delay time≤1S,realize fast startup.
• Adopting LLC scheme for higher energy efficiency>93%
•Power start indicator light, battery charging red green conversion indicator light
■KEY APPLICATIONS
Advertising machine Projector Electric tool
Sales terminal Audio Massage chairr
■CERTIFICATES AND APPROVALS
• Chinese :CCC • CCC: GB 4943.1
• American : UL CUL FCC • UL : UL 62368-1
• European:CB CE GS LVD • EU UK :EN 62368-1 EN 61558-1
• Japan:PSE • PSE: J 62368-1
• United Kingdom :UKCA • UK:BS EN62368-1
• Korea:KC • KC:KC 62368-1



![]()
■Model list and output rating
Model No. | Input rating | Output voltage(Vdc) | Output current(A) | Max output power(W) |
GW360W-xxxyyyyM3 GW360W-xxxyyyyW3z | 100-240V ~ 50/60HZ,4. 5A or 100-120V ~ 50/60HZ,4.5A or 200-240V ~ 50/60HZ,4.5A | 12.0-16.8 | 0.01-25.00 | 300 |
| 18.0-23.9 | 0.01-18.00 | 342 | ||
| 24.0-28.0 | 0.01-15.00 | 360 | ||
28.1-32.0 | 0.01-12.81 | 360 | ||
32.0-38.0 | 0.01-11.21 | 360 | ||
| 38.1-44.9 | 0.01-9.44 | 360 | ||
| 45.0-51.9 | 0.01-8.00 | 360 | ||
52.0-57.0 | 0.01-6.92 | 360 |
■SPECIFICATION
Iutput Characteristics | Rated input voltage | 100-240Vac |
Operating range | 90-264Vac | |
Rated input current | 4.5A | |
input frequency | 50-60Hz +/-3Hz | |
Power Dissipation(No-Load ) | <0.5W | |
Output Characteristics | output voltage | 12.0-57.0Vdc(According to customer demand) |
output current | 0.01-25.0A(According to customer demand) | |
Line regulation | Rated voltage±5% | |
Load regulation | Rated voltage±5% | |
Ripple and noise | 200mVp-p Max | |
Turn on delay time | ≤3S | |
Rise time | 100mS max | |
Hold up time | 10mS min | |
Over-shoot | Rated voltage10% max | |
Efficiency | Meet: DOE VI COC V5 TIER2 | |
Protection Characteristics | Over voltage protection | The power supply shall be hiccup mode, when the output is over voltage, and th e power supply shall not be damaged |
Over current protection | The output shall hiccup when the over current applied to the output, and shall be self-recovery when the fault condition is removed | |
Over Temperature protection | After overheating, the output of the product will be turned off. After troubleshooting the overheating issue, the product will automatically resume normal operation | |
Short circuit protection | The input power shall decrease when the output is short to GND; the power supply shall not damage, and shall be self-recovery when the fault condition is removed | |
Environmental Characteristics | Operating Temperature | 0….+40℃ |
Non-Operating Temperature | -20….+80℃ | |
Operating Humidity | 10%~90% (Non Condensing) | |
Non-Operating Humidity | 10%~90% (Non Condensing) | |
Safety Standards | Dielectric Strength(Hi-pot) | 1500Vac 10mA 60S or2121Vdc 5mA 60S |
Insulation Resistance | 20MΩ min at 500V DC |